lemon-mirror:
Home >> Hyundai >> 1990 >> Excel GLS, Automatic >> Repair and Diagnosis >> Electrical >> Gauges >> Instrument Panel >> Component Testing >> Testing Temperature Sending Unit

Testing Temperature Sending Unit

Remove temperature sender. Using hot water to warm the sending unit, measure resistance readings while warming up sending unit. Resistance readings should be 90-117.5 ohms at 158°F (70°C) and 21.3-26.3 ohms at 239°F (115°C).

Fig 1: Testing Coolant Temperature Sending Unit
G90A02711Courtesy of HYUNDAI MOTOR CO.