lemon-mirror:
Home >> Hyundai >> 2005 >> Sonata GLS >> Repair and Diagnosis >> Engine Performance >> Ignition System >> Engine Electrical System - General Information >> Specifications >> Charging System

Charging System

CHARGING SYSTEM SPECIFICATIONS

Item Specifications
2.4 2.7
Alternator  Type Battery voltage sensing
Rated voltage 13.5V, 90A 13.5V, 110A
Speed 1,000 ~ 18,000 rpm
Voltage regulator Electronic built-in type
Regulator setting voltage 14.4 +/- 0.3V 14.55 +/- 0.2V
Regulator compensation -10 +/- 3mV/°C -3.5 +/- 1 mV/°C
Battery  Type MF 60 AH MF 68 AH
Cold cranking amperage at-18°C (0°C) 550A 600A
Reserve capacity 92min 110min
Specific gravity at 20°C (77°) 1.280 +/- 0.01 1.280 +/- 0.01
NOTE:
  • COLD CRANKING AMPERAGE is the amperage a battery can deliver for 30 seconds and maintain a terminal voltage of 7.2 or greater at a specified temperature. 
  • REVERSE CAPACITY RATING is amount of time a battery can deliver 25A and maintain a minimum terminal voltage of 10.5 at 26.7° C(80° F)