Charging System
CHARGING SYSTEM SPECIFICATIONS
| Item | Specifications | ||
|---|---|---|---|
| 2.7 | 2.0 | ||
| Alternator | Type | Internal sensing | |
| Rated voltage | 13.5V, 120A | 13.5V, 90A | |
| Speed | 1,000 ~ 18,000 rpm | ||
| Voltage regulator | Electronic built-in type | ||
| Regulator setting voltage | 14.55 +/- 0.2V | 14.55 +/- 0.2V | |
| Temperature compensation | -3.5 +/- 1mV/°C | -7 +/- 3mV/°C | |
| Battery | Type | MF 70 AH | MF 60 AH |
| Cold cranking amperage at-18°C (0°F) | 600A | 550A | |
| Reserve capacity | 113min | 92min | |
| Specific gravity at 20°C (77°F) | 1.280 +/- 0.01 | 1.280 +/- 0.01 | |
NOTE:
- COLD CRANKING AMPERAGE is the amperage a battery can deliver for 30 seconds and maintain a terminal voltage of 7.2V or greater at a specified temperature.
- RESERVE CAPACITY RATING is amount of time a battery can deliver 25A and maintain a minimum terminal voltage of 10.5V at 26.7° C (80° F)