Charging System
CHARGING SYSTEM SPECIFICATIONS
| Items | Specification | ||
|---|---|---|---|
| 2.4L | 3.3L | ||
| Alternator | Type | Battery voltage sensing | ← |
| Rate voltage | 13.5 V, 110A | 13.5 V, 130A | |
| Speed in use | 1,000~ 18,000 rpm | ← | |
| Voltage regulator | IC regulator built-in type | ← | |
| Regulator setting voltage | 14.55 ± 0.2 V | 14.2 ~ 14.8 V | |
| Temperature compensation | -3.5 ± 1 mV / °C | -4 ± 4 mV / °C | |
| Battery | Type | MF 68AH | ← |
| Cold cranking amperage [at -18°C(-0.4°F)] | 600 A | ← | |
| Reserve capacity | 110 min | ← | |
| Specific gravity [at 20°C(68°F)] | 1.280 ± 0.01 | ← | |
NOTE:
- COLD CRANKING AMPERAGE is the amperage a battery can deliver for 30 seconds and maintain a terminal voltage of 7.2V or greater at a specified temperature.
- RESERVE CAPACITY RATING is amount of time a battery can deliver 25A and maintain a minimum terminal voltage of 10.5V at 26.7°C(80.1°F).