General Information (Engine Electrical System): Specifications: Specification
Ignition System
IGNITION SYSTEM SPECIFICATION CHART
| Items | Specification | ||
|---|---|---|---|
| Ignition coil | Primary resistance | 0.62 ± 10 % (Ω) | |
| Secondary resistance | 7.0 ± 15 % (kΩ) | ||
| Spark plugs | Unleaded | Type | FK16HQR11 |
| Gap | 1.0 ~ 1.1 mm (0.0394 ~ 0.0433 in.) | ||
Starting System
STARTING SYSTEM SPECIFICATION CHART
| Items | Specification | ||
|---|---|---|---|
| Starter | Rated voltage | 12V, 1.2kW | |
| No. of pinion teeth | 11 | ||
| No-load characteristics | Voltage | 11.5V | |
| Ampere | 90A, MAX | ||
| Speed | 2, 600rpm, MIN | ||
Charging System
CHARGING SYSTEM SPECIFICATION CHART
| Items | Specification | ||
|---|---|---|---|
| 2.0 | 2.4 | ||
| Alternator | Type | Battery voltage sensing | |
| Rate voltage | 13.5 V, 110A | ||
| Speed in use | 1, 000 ~ 18, 000 rpm | ||
| Voltage regulator | IC regulator built-in type | ||
| Regulator setting voltage | 14.4 ± 0.1V | ||
| Temperature compensation | -3.5 ± 1mV / °C | ||
| Battery | Type | 48-23GL | 54-26GL |
| Cold cranking amperage [at -18°C (-0.4°F)] | 550A | 600A | |
| Reserve capacity | 92min | 110min | |
| Specific gravity [at 25°C (77°F)] | 1.280 ± 0.01 | ||
CAUTION:
- COLD CRANKING AMPERAGE is the amperage a battery can deliver for 30 seconds and maintain a terminal voltage of 7.2V or greater at a specified temperature.
- RESERVE CAPACITY RATING is amount of time a battery can deliver 25A and maintain a minimum terminal voltage of 10.5V at 26.7°C (80.1°F).