Repair procedures: Removal
- Disconnect the negative terminal (A) from the battery.
Tightening torque:
3.9 ~ 5.9 N.m (0.4 ~ 0.6 kgf.m, 2.9 ~ 4.3 lb-ft)
- Disconnect the starter cable (A) from the B terminal on the solenoid, and the connector (B) from the S terminal.
- Loosen the starter mounting bolts and then remove the starter.
Tightening torque:
49.0 ~ 63.7 N.m (5.0 ~ 6.5 kgf.m, 36.2 ~ 47.0 lb-ft)
- Installation is reverse order of removal.