Door Switch Circuit Check

  1. Turn ignition switch to LOCK position. Using a voltmeter, backprobe appropriate terminals at Smart Entrance Control Unit (SECU) harness connector with door in appropriate position. See DOOR SWITCH INPUT VOLTAGE TEST  table. See Figure . If voltage is not as specified, go to next step. If voltage is as specified, door switch input signals are okay at this time.
  2. Test malfunctioning door switch. See DOOR SWITCH  under COMPONENT TESTS. If door switch is defective, replace door switch. If door switch is okay, check door switch ground circuit and signal circuits for opens and/or shorts and repair as necessary. See WIRING DIAGRAMS  .
DOOR SWITCH INPUT VOLTAGE TEST

Door Position Terminal No. (Wire Color) Voltage
Driver's Door
Open 15 (Green/Red) 0
Closed 15 (Green/Red) 12
Passenger's Door
Open 35 (Yellow) 0
Closed 35 (Yellow) 12
Any Door (1)
Open 16 (Red/Yellow) 0
Closed 16 (Red/Yellow) 12
(1) Check voltage at terminal No. 16 at SECU harness connector with each door open and closed, including rear hatch.