lemon-mirror:
Home >> Infiniti >> 2001 >> G20 Base, Automatic, RE4F03W >> Repair and Diagnosis >> Brakes >> Traction Control >> Anti-Lock >> Scan Tool Usage >> Using Consult-II >> Data Monitor Procedure

Data Monitor Procedure

  1. Turn ignition switch OFF.
  2. Connect CONSULT-II to data link connector. See Figure .
  3. Turn ignition switch ON.
  4. Touch "START" on CONSULT-II screen.
  5. Touch "ABS".
  6. Touch "DATA MONITOR".
  7. Touch "SETTING" on "SELECT MONITOR ITEM" screen.
  8. Touch "START" on "SET RECORDING COND" screen.
  9. Touch "START" on "SELECT MONITOR ITEM".
  10. For data monitor mode descriptions, see Fig 1 .
Fig 1: Data Monitoring Mode With CONSULT-II
G00190755Courtesy of NISSAN MOTOR CO., U.S.A.