lemon-mirror:
Home >> Infiniti >> 2004 >> M45 >> Repair and Diagnosis >> Engine Performance >> Engine Control System >> DTC P0605: ECM >> DTC Confirmation Procedure >> Procedure For Malfunction B >> With CONSULT-II

With CONSULT-II

  1. Turn ignition switch ON and wait at least 2 seconds.
  2. Select "DATA MONITOR" mode with CONSULT-II.
    Fig 1: Scan Tool Display - Data Monitor
    G00796170Courtesy of NISSAN MOTOR CO., U.S.A.
  3. Turn ignition switch OFF, wait at least 10 seconds, and then turn ON.
  4. If 1st trip DTC is detected, go to DIAGNOSTIC PROCEDURE .