Component Function Check
- CHECK FUNCTION
- Select "SLIDE PULSE" in "Data Monitor" mode with CONSULT-III.
- Check sliding sensor signal under the following conditions.MONITOR ITEM STATUS REFERENCE
Monitor item Condition Valve SLIDE PULSE Seat sliding Operate (forward) Change (increase)(1) Operate (backward) Change (decrease)(1) Release No change(1) (1) The value at the seat position attained when the battery is connected is considered to be 32768.
Is the indication normal?
YES: INSPECTION END
NO: Perform daiagnosis procedure. Refer to "DIAGNOSIS PROCEDURE ".