Without Engine Running

The fuel vapor taken up into the roll-over and float valve is routed into check and relief valve. When vacuum becomes 1.0-1.4 in. Hg, the check valve opens and allows vapor into canister. While check valve is open, valve at air cleaner side remains closed to prevent flow of vapor into air cleaner.