lemon-mirror:
Home >> Isuzu >> 1993 >> Stylus Automatic >> Repair and Diagnosis >> Electrical >> Gauges >> Instrument Panel >> Component Testing >> Voltmeter

Component Testing: Voltmeter

Disconnect battery negative cable. Remove instrument cluster. See INSTRUMENT CLUSTER  under REMOVAL & INSTALLATION. Using ohmmeter, measure resistance between IGN and GND terminals. SeeFig 1 . Resistance should be about 178 ohms. If resistance reading is not as specified, replace voltmeter.

Fig 1: Testing Voltmeter
G93E01624Courtesy of ISUZU MOTOR CO.