  1. Remove two 11 mm bolts from valve body (28), then remove gaskets and transfer plate (1).
  2. Remove manual valve (2).
  3. Push in band control solenoid (3) to compress waved washer (5), and remove pin (4).
  4. Remove band control solenoid (3) and waved washer (5).
  5. Remove spring pin (6) with a 3 mm diameter punch.
  6. Remove solenoid A (7) by grasping the metal tip. Do not grasp the connector housing.
  7. Remove retainer (8), 1-2/3-4 shift valve (9), and spring (10).
  8. Remove spring pin (11) with a 3 mm diameter punch.
  9. Remove solenoid B (12) by grasping the metal tip. Do not grasp the connector housing.
  10. Remove retainer (13), 2-3 shift valve (14), and spring (15).
  11. Remove spring pin (16), plug (17), spring (18), and low pressure control valve (19).
  12. Remove spring pin (20), plug (21), and band control screen assembly (22).
  13. Remove spring pin (23), plug (24), 1-2 accumulator valve (25), and 1-2 accumulator control valve (26).
  14. Remove check ball (27) from valve body (28).