lemon-mirror:
Home >> Isuzu >> 2002 >> Rodeo Sport 2.2 D, Automatic >> Repair and Diagnosis >> Electrical >> Starters >> Starter Specifications

Starter Specifications

STARTER SPECIFICATIONS

Application Specification
Brush
Standard .59" (15 mm)
Limit .43" (11.0 mm)
Brush Spring
Standard 39-52 Lbs. (18-24 N)
Limit 26 Lbs. (12 N)
Commutator Diameter
Standard 1.18" (30 mm)
Limit 1.14" (29mm)
Commutator Mica Depth
Standard .0177-.0295" (.45-.75 mm)
Limit .008" (.2 mm)
Commutator Runout
Limit .0157" (0.4 mm)
Bench Testing (No Load)
Minimum Volts 11.5
Maximum Amps 90
Minimum RPM 3000
On-Vehicle Testing (Under Load)
Minimum Volts 8.5
Maximum Amps 350
Minimum RPM 1000