Load Test
- Connect a voltmeter and a battery load tester across the battery terminals.
- Apply 300 ampere load for 15 seconds to remove surface charge from the battery. Remove load.
- Wait 15 seconds to let battery recover. Then apply specified load from specifications (See MAIN DATA AND SPECIFICATIONS
.
Read voltage after 15 seconds, then remove load.
- VOLTAGE DOES NOT DROP BELOW THE MINIMUM LISTED IN THE TABLE -The battery is good and should be returned to service.
- VOLTAGE IS LESS THAN MINIMUM LISTED - Replace the battery.
BATTERY MINIMUM VOLTAGE LISTESTIMATED TEMPERATURE MINIMUM VOLTAGE °F °C V 70 21 9.6 60 16 9.5 50 10 9.4 40 4 9.3 30 -1 9.1 20 -7 8.9 10 -12 8.7 0 -18 8.5 The battery temperature must be estimated by feel and by the temperature the battery has been exposed to for the preceding few hours.