Reference Number(s): SSM59017, Date of Issue:  Spetember 20, 2012
JAGUAR: S-TYPE/X200; XK-SERIES/X100; XJ/X350
CATEGORY: Driveline

SERVICE INFORMATION

Symptom 501000 Automatic Transmission Concerns

ISSUE

Vehicle lines affected: S-TYPE (X202), XJ (X350), or XK (X100) vehicles with ZF transmission

When using SDD to re-configure the TCM as 'Existing Module', the procedure may fail with the following message: "VERONA: SOCKET TX ERROR" and this will leave the TCM in a non-functional state.

ACTION

Content

If this message appears do not turn the ignition off. Ignore the 'Switch Ignition Off' on screen instruction, leave the ignition on and configure the TCM as a 'New Module'. If the ignition has been switched off, close the current session, start a new session and configure the TCM as a 'New Module'

If the above fails please contact the local Technical Support hotline for assistance.