Reference Pressure Regulator
Install "T" fitting at connection "A". See Fig 1. Connect a vacuum gauge to "T" fitting. Start and run engine at idle. Note vacuum reading. Compare reading with specification, and replace pressure regulator if vacuum reading is incorrect. See ALTITUDE COMPENSATED VACUUM table.
ALTITUDE COMPENSATED VACUUM
| Altitude (Ft.) | Vacuum (Inches Hg) |
|---|---|
| 0 | 8-10 |
| 1000 | 7-9 |
| 2000 | 6-8 |
| 3000 | 4.5-6.5 |
| 4000 | 3-5 |
| 5000 | 2-4 |