Starting System: Starting: Specifications: Starter
| Starter Motor and Solenoid | |
|---|---|
| Engine Application | 2.4L, 4.0L |
| Power Rating |
2.4L - 1.4 Kilowatt (1.9 Horsepower) 4.0L - 1.4 Kilowatt (1.9 Horsepower) |
| Voltage | 12 Volts |
| ** Number of Permanent Magnets | 6 |
| Number of Brushes | 4 |
| Drive Type | Planetary Gear Reduction |
| Free Running Test Voltage | 11.2 Volts |
| Free Running Test Maximum Amperage Draw |
90 Amperes |
| Free Running Test Minimum Speed |
2.4L - 24400 RPM 4.0L - 2500 RPM |
| Solenoid Closing Maximum Voltage Required | 7.8 Volts |
| *Cranking Amperage Draw Test |
2.4L - 160 Amperes 4.0L - 160 Amperes |
| * Test at operating temperature. Cold engine, tight (new) engine or heavy oil will increase starter amperage draw. | |
| ** The starter is equipped with permanent magnets. Never strike the starter case to attempt to loosen a sticking/stuck armature as permanent magnets may crack or break. | |