Brush Replacement
- Measure the length of the brush protrusion shown in the illustration, and replace the brush if the measured value is below the limit value.
Limit: 2 mm (0.079 in.) or less
- The brush can be removed if the solder of the brush lead wire is removed.
- When installing a new brush, insert the brush into the holder, and then solder the lead wire.