Lock-Up Operating Condition Table
LOCK-UP OPERATING CONDITION REFERENCE
| Select lever | D range | Sports mode | |||
|---|---|---|---|---|---|
| Gear position | 5 | 4 | 3 | 5 | 4 |
| Lock-up | X | - | - | X | X |
| Slip lock-up | X | X | - | - | - |
Lock-up control valve control
- In the lock-up control valve, there is operating fluid pressure circuit linked into the lock-up piston and lock-up solenoid operates valve shift in response to a signal from the A/T control unit.
- Operating fluid pressure circuit that is applied to the lock-up piston chamber is controlled with the release or apply sides.