Repair procedures: Inspection
- Connect a scantool on the Data Link Connector (DLC).
- Turn the ignition switch ON.
- Measure the output voltage of the APS 1 and 2 at C.T and W.O.T. Refer to "SPECIFICATION ".
- Turn ignition switch OFF and disconnect the scantool from the DLC.
- Disconnect APS connector.
- Measure resistance between the APS terminals 4 and 5 (APS 1). Refer to "SPECIFICATION ".
- Measure resistance between the APS terminals 1 and 6 (APS 2). Refer to "SPECIFICATION ".