Neutralizing Of ECM
The ECM can be set to the "neutral" status by a tester.
A valid ignition key is inserted and after ignition on is recorded, the ECM requests the vehicle specific data from the tester. The communication messages are described at "Neutral Mode" After successfully receiving the data, the ECM is neutralized.
The ECM remains locked. Neither the limp home mode nor the "twice ignition on" function, is accepted by the ECM.
The teaching of keys follows the procedure described for the virgin ECM. The vehicle specific data have to be unchanged due to the unique programming of the transponder. If data should be changed, new keys with a virgin transponder are requested.
This function is for neutralizing the ECM and Key. Ex) when lost key, Neutralize the ECM then teach keys.
(Refer to: Teaching Procedures when Key & PIN Code the ECM are set to the "neutral" status by a scanner. If wrong vehicle specific data have been sent to immobilizer three times continuously or intermittently, the immobilizer will reject the request to enter neutral mode for one hour. Disconnecting the battery or other manipulation cannot reduce this time. After connecting the battery the timer starts again for one hour.
- Neutralizing setting condition
- In case of ECM status "Learnt" regardless of user password "Virgin or Learnt"
- Input correct PIN code by scanner.
- Neutralizing meaning.
: PIN code (6) & user password (4) deletion.
: Locking of ECM (except key teaching permission)
- Neutralizing meaning:
- PIN Code (6) & User P/Word (4) deletion
- Locking of EMS (except Key Learning permission)
| EMS/Function | Engine Running | Learning | |||
|---|---|---|---|---|---|
| Learnt Key | Limp home | Twice Ignition | Key | User Password | |
| Neutral | No | No | No | Yes | No |