VVT Sensor: Removal
- REMOVE V-BANK COVER SUB-ASSEMBLY (See REMOVAL )
- REMOVE AIR CLEANER INLET COVER SUB-ASSEMBLY (See REMOVAL )
- REMOVE NO. 1 AIR CLEANER INLET (See REMOVAL )
- REMOVE AIR CLEANER ASSEMBLY LH
- Disconnect the MAF meter connector.
- Remove the 2 clips, hose clamp and air cleaner cap.
- Remove the element from the air cleaner case.
- Remove the 2 nuts, clip and air cleaner case.
- REMOVE AIR CLEANER ASSEMBLY
- Disconnect the MAF meter connector.
- Remove the 2 clips, hose clamp and air cleaner cap.
- Remove the element from the air cleaner case.
- Remove the 2 nuts, clip and air cleaner case.
- REMOVE VVT SENSOR
- Disconnect the 4 VVT sensors.
- Remove the 4 bolts and 4 VVT sensors.