lemon-mirror:
Home >> Lexus >> 2011 >> GX 460 >> Repair and Diagnosis >> Electrical >> Starter >> Starting System (Service Specifications) >> 1UR-FE Starting >> Service Data >> Service Data

Service Data

Starter Standard current 190 A or less at 11.5 V
Starter armature Circle runout Maximum 0.05 mm (0.00197 in.)
Commutator Standard diameter 35.0 mm (1.38 in.)
Minimum diameter 34.0 mm (1.34 in.)
Standard undercut depth 0.7 mm (0.0276 in.)
Minimum undercut depth 0.2 (0.00787 in.)
Brush Standard length 15.0 mm (0.591 in.)
Minimum length 9.0 mm (0.354 in.)
Starter brush holder assembly Standard spring load 22 to 28 N (2 to 3 kgf, 4.8 to 6.2 lbf)
Minimum spring load 12 N (1 kgf, 2.8 lbf)