Remote Power Window Switch
NOTE:
Remote power window switches contain relays. To test switch functions, connect one end of a jumper wire to terminal C2-3 and the other end to battery voltage. Connect one end of a second jumper wire to ground and the other end to terminal C1-4.
Remove remote power window switch from door. See, under REMOVAL & INSTALLATION, POWER WINDOW SWITCH . Using an ohmmeter, check for continuity between indicated terminals with switch in appropriate position. See Fig 1 . See POWER WINDOW REMOTE SWITCH CONTINUITY TEST table. If continuity is not as specified, replace power window switch(es).
POWER WINDOW REMOTE SWITCH CONTINUITY TEST
| Switch Position | Continuity Between Terminals | ||
|---|---|---|---|
| Neutral | C1-2, C1-3 & C1-4 | ||
| Neutral | C2-1, C2-4 & (1) C1-4 | ||
| Neutral | C1-1 & C2-3 | ||
| Up | C1-3 & C1-1 | ||
| Neutral | C1-2 & C2-3 | ||
| Neutral | C2-4 & (1) C1-4 | ||
| Down | C2-3 & C1-4 | ||
| Neutral | C1-2 & C1-1 | ||
|
|||