Cold Start THERMOSWITCH
Remove cold start thermoswitch. Place thermoswitch and thermometer in container of coolant. Connect ohmmeter to thermoswitch terminals. Slowly heat coolant. Note resistance at specified temperatures. See COLD START THERMOSWITCH RESISTANCE table. Replace thermoswitch as necessary.
COLD START THERMOSWITCH RESISTANCE
| Temperature | Ohms |
|---|---|
| 68°F (20°C) | 25-35 |