Disabling System
- Obtain radio code from customer and deactivate audio anti-theft function. Turn ignition off. Disconnect and shield negative battery cable. Wait at least one minute for back-up power supply to be depleted.
- Disconnect diagnostic module connectors located at base of steering column and connect Short Circuit Connectors (49-H066-004 ) to diagnostic module harness connectors. See Figure .