Brush Test: MPV
- Connect one ohmmeter lead to positive brush holder and other lead to negative brush holder. If continuity exists, replace brush holder assembly.
- Check brush length. Minimum brush length is .28" (7.0 mm). If brush length is less than specified, replace brushes.