Sub-Switch Test
Disconnect sub-switch harness connector. Check for continuity between specified sub-switch terminals with sub-switch button in specified position. See SUB-SWITCH CONTINUITY TEST table. See Fig 1 or Fig 2 . If continuity is not as specified, replace sub-switch.
SUB-SWITCH CONTINUITY TEST
| Application & Switch Position | Continuity Between Terminals | |
|---|---|---|
| Millenia, MPV & Protege | ||
| UP | A & E; B & D | |
| DOWN | B & E; D & F | |
| Off (Neutral) | A & E; D & F | |
| 626 | ||
| UP | B & C; A & E | |
| DOWN | B & E; C & F | |
| Off (Neutral) | A & E; C & F | |