lemon-mirror:
Home >> Mazda >> 2002 >> 626 ES, Automatic >> Repair and Diagnosis >> Electrical >> Charging Systems >> Generators & Regulators >> On-Vehicle Tests >> Back-Up Current

Back-Up Current

  1. Verify that the ignition switch is at LOCK position and that the ignition key has been removed.
  2. CAUTION: Operating electrical loads while measuring the back-up current can damage the circuit tester.
  3. Disconnect the negative battery cable.
  4. Measure the back-up current between the negative battery terminal and the negative battery cable.
    • If the current exceeds 20 mA, remove the fuse in the main fuse block and the fuse block one by one while measuring the back-up current.
    • Inspect and repair harnesses and connectors of the fuse at which the current reduces.