Generator Inspection: Generator: Current
NOTE:
- Since the charging current decreases rapidly after starting the engine, perform the following procedure quickly, and read the maximum current value.
- Verify that the battery is fully charged.
- Charge if necessary.
- Verify that the drive belt deflection/tension is within the specification. (L3) (See DRIVE BELT INSPECTION [L3] .)
- Disconnect the negative battery cable.
- Connect a tester cable of reading 120 A or more between generator terminal B and the wiring harness.
- Turn off all electrical loads.
- Start the engine and increase the engine speed to 2,000-2,500 rpm.
- Turn the following electrical loads on and verify that the current reading increases.
- Headlights
- Blower motor
- Rear window defroster
- If generator terminal B current does not increase, repair or replace the generator if necessary.
NOTE:- Current required for generating power varies with electrical loads applied.
Standard current (Reference)
Measuring conditions:
Room temperature: 20 °C {68 °F}
Voltage: 13.5 V
Engine hot
ENGINE SPEED SPECIFICATIONEngine speed (rpm) Terminal B current (A)(1) L3 AJ 1,000 0(1)-80 0(1)-90 2,000 0(1)-100 0(1)-105 (1) Lower limit of current must be more than 0 A.