Continuity Inspection
- Remove the battery cover.
- Disconnect the negative battery cable. (See BATTERY REMOVAL/INSTALLATION [LF] .)
- Disconnect the fuel pump unit connector. (See FUEL PUMP UNIT REMOVAL/INSTALLATION .)
- Inspect for continuity between fuel pump unit terminals B and D.
- If there is continuity, perform the CIRCUIT OPEN/SHORT INSPECTION .
- If there is no continuity, replace the fuel pump. (See FUEL PUMP UNIT DISASSEMBLY/ASSEMBLY .)