Check code 25
CHECK CODE 25 DIAGNOSTIC PROCEDURE
| Check code 25 | Operation signal to water temperature gauge | ||
|---|---|---|---|
| INSPECTION | INDICATION | SITUATION | ACTION |
| Wait for 2 seconds after selecting check code 25. | Water temperature gauge indicates in following order for every 2 seconds.
|
Water temperature gauge is okay. | |
| Other than stated above. | Replace instrument cluster. | ||
| Replace instrument cluster. | |||