Freeze Frame Data Table

FREEZE FRAME DATA CHART

Acronym Description Measurement Units
AAT Ambient Air Temperature Degrees
AIR Secondary Air Status  
APP_D Accelerator Pedal Position D %
APP_E Accelerator Pedal Position E %
APP_F Accelerator Pedal Position F %
BARO Barometric Pressure kPa
CATTEMP11 Catalyst Temperature Bank 1, Sensor 1 Degrees
CATTEMP21 Catalyst Temperature Bank 2, Sensor 1 Degrees
CLRDIST Distance Since Last Code Cleared Km
ECT Engine Coolant Temperature Degrees
EQ_RAT Commanded Equivalence Ratio Unit
EQ_RAT11 Lambda Value Bank 1, Sensor 1 Unit
EQ_RAT21 Lambda Value Bank 2, Sensor 1 Unit
EVAPPCT Commanded Evaporative Purge %
EVAPVP Evaporative System Vapor Pressure Pa
FLI Fuel Level Input %
FRP Fuel Rail Pressure kPa
FUELSYS1 Open/Closed Loop1 OL/CL/OL DRIVE/OL FAULT/CL FAULT
FUELSYS2 Open/Closed Loop2 OL/CL/OL DRIVE/OL FAULT/CL FAULT
IAT Intake Air Pressure Degrees
LFT1 Long Term Fuel Bank 1 %
LFT2 Long Term Fuel Bank 2 %
LOAD Calculated Load Value %
MAF Mass Air Flow Rate g/s
MAP Manifold Absolute Pressure kPa
O2S11 Bank 1 Upstream Oxygen Sensor (11) Volts/mA
O2S12 Bank 1 Downstream Oxygen Sensor (12) Volts
O2S21 Bank 2 Upstream Oxygen Sensor (21) Volts/mA
O2S22 Bank 2 Downstream Oxygen Sensor (22) Volts
RPM Engine RPM RPM
RUNTM Run Time Seconds
SHRTFT1 Short Term Fuel Bank 1 %
SHRTFT2 Short Term Fuel Bank 2 %
SPARKADV Spark Advance Degrees
TAC_PCT Commanded Throttle Acutator %
TP Absolute Throttle Position %
TP_REL Relative Throttle Position %
VS Vehicle Speed km/h-mph
WARMUPS Number Of Warmups Since Code Cleared Units

Some unique PIDs are stored in the Keep Alive Memory of the (KAM) of the PCM to help in diagnosing the root cause of misfires. These PIDs are collectively called misfire freeze-frame (MFF) data. These parameters are separate from the generic freeze-frame data that is stored for every MIL code. They are used for misfire diagnosis only. The MFF data could be more useful for misfire diagnosis than the generic freeze frame data. It is captured at the time of the highest misfire rate, and not when the DTC is stored at the end of a 1,000 or 200 revolution block. (Generic freeze-frame data for misfire can be stored minutes after the misfire actually occurred).

NOTE:
  • MFF PIDs are supported on all vehicles but may not be available on all scan tools because enhanced PID access may vary by scan tool manufacturer.