Metering Oil Pump Driver Inspection
- Remove the battery cover. (See BATTERY REMOVAL/INSTALLATION [13B-MSP] .)
- Disconnect the negative battery cable.
- Disconnect the metering oil pump driver connector.
- Verify that the resistance is as indicated in the table.
- If not within the specification, replace the metering oil pump driver. (See METERING OIL PUMP DRIVER REMOVAL/INSTALLATION .)
Metering Oil Pump Driver Resistance
METERING OIL PUMP DRIVER RESISTANCE SPECIFICATIONS
| Terminal | Resistance |
|---|---|
| B-D C-B C-F D-F |
50-100 kilohm |
| D-A D-E |
1 Megohm |