lemon-mirror:
Home >> Mercedes Benz >> 1984 >> 190D Automatic >> Repair and Diagnosis >> Engine Performance >> System >> EGR System - Diesel >> Testing >> TD-Signal

EGR System - Diesel: Testing: TD-Signal

Using volt/ohmmeter, connect positive lead to terminal 2 of plug connection for TD input. Measure voltage at idle speed, should be approx. 2.8 volts. If not, check activation of RPM sensor for engine. If no activation, replace sensor.