Lambda Control

Lambda control is integrated in ECU functions. Output signal to the differential pressure regulator used in Lambda control.

Signal range of differential pressure regulator current is 0-16 mA. A minimum signal of approximately 8 mA is needed to affect a change.

Lambda control is made inoperative by signal from ECU under these conditions:

CAUTION: With ignition on or the engine running, the plug on the CIS-E control unit must not be disconnected. Voltage or current peaks can damage the control unit.