Air Control/Shut-Off Valve

Verify that air flow is present at valve inlet by disconnecting air supply hose momentarily at valve inlet. See Figure. Disconnect hose from outlet and vacuum line from nipple. With engine running at 1500 RPM, air should be heard and felt at outlet. Connect direct manifold vacuum to nipple. There should be little or no air flow at valve outlet.