lemon-mirror:
Home >> Mitsubishi >> 2006 >> Outlander LS, AWD, Automatic >> Repair and Diagnosis >> Electrical >> Charging Systems >> Charging System >> Generator Assembly >> Inspection >> Rectifier Check

Rectifier Check

  1. Check for continuity between the positive rectifier and the stator coil lead connection terminal with a tester. If there is continuity between the terminals, the diode is shorted, so replace the rectifier.
    Fig 1: Checking Continuity Between Positive Rectifier And Stator Coil Lead Connection Terminal
    G04302068Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
  2. Check for continuity between the negative rectifier and the stator coil lead connection terminal with a tester. If there is continuity between the terminals, the diode is grounded, so replace the rectifier.
    Fig 2: Checking Continuity Between Negative Rectifier And Stator Coil Lead Connection Terminal
    G04302069Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
  3. Check for continuity of the three diodes by connecting an ohmmeter to both ends of each diode. If there is continuity between the directions, or if there is no continuity, the diode is damaged, so replace the rectifier.
    Fig 3: Checking Continuity Of Three Diodes By Connecting An Ohmmeter To Both Ends Of Each Diode
    G04302070Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.