3.7L /4.7L
Fig 1: Identifying Generator, B+ Terminal Mounting Nut, Plastic Insulator Cap And Field Wire Connector
WARNING:
DISCONNECT NEGATIVE CABLE FROM BATTERY BEFORE REMOVING BATTERY OUTPUT WIRE (B+ WIRE) FROM GENERATOR. FAILURE TO DO SO CAN RESULT IN INJURY OR DAMAGE TO ELECTRICAL SYSTEM.
- Disconnect negative battery cable at battery.
- Remove generator drive belt. Refer to COOLING for procedure.
- Unsnap plastic insulator cap (3) from B+ output terminal.
- Remove B+ terminal mounting nut (2) at rear of generator. Disconnect terminal from generator.
- Disconnect field wire connector (4) at rear of generator by pushing on connector tab.
- Remove 1 rear vertical generator mounting bolt (2).
- Remove 2 front horizontal generator mounting bolts (1).
- Remove generator from vehicle.