Standard Waveform

Observation Conditions
FUNCTION SPECIAL PATTERNS
Pattern height Variable
Variable knob Adjust while viewing the wave pattern
Pattern selector Raster
Engine revolutions Curb idle speed
Fig 1: Generator Voltage Graph
G09640980Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
Fig 2: Generator Voltage Waveform
G09640981Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
NOTE: The voltage waveform of the generator "B" terminal can undulate as shown in the illustration above . This waveform is produced when the regulator operates according to fluctuations in the generator load (current), and is normal for the generator.
If the ripple height is abnormally high (approximately 2 V or more during idling), the wires between the generator "B" terminal and the battery have broken due to fuse blowing, etc. The generator is usually operating properly.