Generator Assembly: Inspection: Stator

  1. Check the electrical continuity between the stator coil terminals.
  2. Check the electrical continuity of the points shown in the table below.Confirm that there is electrical continuity.

    If there is not, replace the stator.

    Terminal connector of tester Electrical continuity
    1 - 2 Presence of electrical continuity
    1 - 3
    2 - 3
    4 - 5
    4 - 6
    5 - 6
    Fig 1: Checking Electrical Continuity Between Stator Coil Terminals
    G07047291Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
  3. Check the insulation between the stator coil terminal and the core.
  4. Check the electrical continuity of the points shown in the table below. Confirm that there is not electrical continuity.

    If there is, replace the stator.

    Terminal connector of tester Electrical continuity
    1 - Core Absence of electrical continuity
    2 - Core
    3 - Core
    4 - Core
    5 - Core
    6 - Core
    Fig 2: Checking Insulation Between Stator Coil Terminal And Coil
    G07047292Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
  5. Check the insulation between coil terminals of each group.
  6. Check the electrical continuity of the points shown in the table below. Confirm that there is not electrical continuity.
Fig 3: Checking Insulation Between Coil Terminals Of Each Group
G07047293Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.

If there is, replace the stator.

Terminal connector of tester Electrical continuity
1 - 4 Absence of electrical continuity
1 - 5
1 - 6
2 - 4
2 - 5
2 - 6
3 - 4
3 - 5
3 - 6