Abnormal Waveforms

PROBABLE CAUSE: Open circuit or short circuit in diode

Fig 1: Abnormal Waveforms - Example 1
G05393699Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.

PROBABLE CAUSE: Open circuit in stator coil (In stator coil)

Fig 2: Abnormal Waveforms - Example 2
G05393700Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.

PROBABLE CAUSE: Open circuit in stator coil (Open circuit between stator coil and diode)

Fig 3: Abnormal Waveforms - Example 3
G05393701Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.

PROBABLE CAUSE: Short circuit in stator coil

Fig 4: Abnormal Waveforms - Example 4
G05393702Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.