lemon-mirror:
Home >> Mitsubishi >> 2019 >> Outlander ES, FWD >> Repair and Diagnosis >> Electrical >> Charging Systems >> Charging System >> On-Vehicle Service >> Waveform Check Using An Oscilloscope >> Example Of Abnormal Waveforms

Example Of Abnormal Waveforms

NOTE:
  1. The size of the waveform patterns differs largely, depending on the adjustment of the variable knob on the oscilloscope.
  2. Identification of abnormal waveforms is easier when there is a large output current (regulator is not operating). (Waveforms can be observed when the headlights are illuminated).
  3. Check the conditions of the generator malfunction light (illuminated/not illuminated). Also, check the charging system totally.
Abnormal waveform Problem cause
2.4L Engine 3.0L Engine
Example 1
G05393699
G13088684
Open diode
Example 2
G13088685
G13088686
Short in diode
Example 3
G13088687
G13088688
Broken wire in stator coil
Example 4
G13088689
G05375400
Short in stator coil