Position Indicator Check
| Terminal number | Item | Selector lever operation | Normal conditions | |
|---|---|---|---|---|
| Continuity (Resistance) | Illumination/extinction | |||
| 4 - 5 | Position indicator (R) | R | No continuity | Illumination |
| 4 - 6 | Position indicator (N) | N | No continuity | Illumination |
| 4 - 12 | Position indicator (D) | D | No continuity | Illumination |
| 4 - 13 | Position indicator (B) | B | No continuity | Illumination |
| 2 - 9 | EV priority mode switch | Don not press the switch | No continuity | - |
| Press and hold the switch | Continuity exists (2Ω or less) | - | ||
| 1 - 8 | SAVE/CHARGE mode switch | Don not press the switch | No continuity | - |
| Press and hold the switch | Continuity exists (2Ω or less) | - | ||