Locked Resistance Test

Mount starter in test bench. Follow test equipment manufacturers instructions. With battery voltage adjusted to 4 volts, amperage draw should be as shown in specifications.

STARTER SPECIFICATIONS

Application Amps.
Cranking Amperage Test  
  Model No. 3755900 (1.5 HP) 165-180
  Model No. 3755250 (1.8 HP) 180-200
Solenoid Amperage Test (6 volts @ 77°F)  
  Pull-In Circuit 13-15
  Hold-In Circuit 8-9
No Load Amperage Test  
  Model No. 3755900 (3700 RPM minimum) 90
  Model No. 3755250 (5700 RPM minimum) 90
Lock Resistance Amperage Test 475-550