Intake Air Temperature Sensor: Code 3
Disconnect airflow sensor connector. Check intake air temperature sensor by measuring resistance between terminals No. 2 and 4. See Fig 1 . Replace airflow sensor assembly if not to specification.
INTAKE AIR TEMPERATURE SENSOR RESISTANCE
| Temperature °F (°C) | Resistance Ohms |
|---|---|
| 32 (0) | 6000 |
| 68 (20) | 2700 |