Armature Test
- Test armature for shorted coils with a growler. Check for grounded coils with a test light. Place one lead on armature shaft and other lead on commutator. Test light should not light. If test light lights, armature is grounded. Replace armature.
- Turn commutator if it is rough, worn or has protruding insulation. DO NOT turn to less than 1.65" (41.9 mm) diameter. Sand commutator lightly with No. 240 grit emery paper and clean out the slots.
CAUTION:
Some starters have a molded-type commutator. DO NOT
undercut insulation or commutator will be seriously damaged.