lemon-mirror:
Home >> Pontiac >> 2001 >> Aztek Base, FWD >> Repair and Diagnosis >> Transmission >> Transfer Case >> Transfer Case - STEYR >> Specifications >> Fastener Tightening Specifications

Fastener Tightening Specifications

Fastener Tightening Specifications

Application Specification
Metric English
Case-Left Drain Plug 32 N.m 24 lb ft
Case M10 Bolts 60 N.m 44 lb ft
Case M8 Bolts 32 N.m 24 lb ft
Differential Carrier Nut 500 N.m 369 lb ft
Extension Housing Bolts 32 N.m 24 lb ft
Extension Housing Drain Plug 32 N.m 24 lb ft
Extension Housing Fill Plug 32 N.m 24 lb ft
Holding Fixture J 44755 M10 Bolts 50 N.m 37 lb ft
Holding Fixture J 44755 M8 Bolts 25 N.m 18 lb ft
Output Driven shaft Nut (Flange Nut) 250 N.m 185 lb ft
Output Driveshaft Housing M10 Bolts 60 N.m 44 lb ft
Output Driveshaft Housing M8 Bolts 32 N.m 24 lb ft
Output Driveshaft Nut 505 N.m 372 lb ft
Speed Sensor Bolt 10 N.m 106 lb in
Transfer Case-to-Transaxle Bolts - in sequence 50 N.m 37 lb ft
Transfer Case-to-Transaxle M10 Brace Bolts 56 N.m 41 lb ft
Transfer Case-to-Transaxle M8 Brace Bolts 32 N.m 24 lb ft