Component Testing
- Measure for 70-110 ohms between terminals 85 and 86 of the relay.
- If the resistance is not within the specified range, replace the relay.
- Measure for infinite resistance between terminals 30 and 86 of the relay.
- If continuity is detected, replace the relay.
- Measure for infinite resistance between terminals 30 and 87 of the relay.
- If continuity is detected, replace the relay.
- Measure for infinite resistance between terminals 30 and 85 of the relay.
- If continuity is detected, replace the relay.
- Measure for infinite resistance between terminals 85 and 87 of the relay.
- If continuity is detected, replace the relay.
- Connect a 20-amp fused jumper wire from the battery positive cable at the battery, to relay terminal 85. Connect a jumper wire from the negative battery cable at the battery, to relay terminal 86. Measure for less than 2 ohms between terminals 30 and 87 of the relay, with a DMM.
- If the resistance measures more than 2 ohms, replace the relay.